FT2232HL
A dual-channel Hi-Speed USB interface for an approved LQFP-64 design. Send your quantity and build date with the channel use and configuration your product expects.
Set the requirement before reviewing a lot.
ICstoq is an independent distributor supplying through our inventory and established supply relationships. Send the exact order code and required quantity; the quotation confirms the available lot and agreed conditions.
Send this part for reviewConfirm FT2232HL, not FT2232HQ
The HL option is LQFP-64. Confirm the released footprint and inspect lead alignment and coplanarity appropriate to that package.
Define the two channels
State whether each channel is used for UART, FIFO or an MPSSE protocol such as JTAG, SPI or I²C. Do not substitute a single-channel part on the basis of a similar name.
Specify host and configuration
Include your approved driver or host tool and any EEPROM configuration. Agree who programs it and whether testing may change the device state.
See the supplied shipment photographs.
Review the device marking, carrier tape and packaging prepared for laboratory inspection. Current quantity, lot condition and delivery are confirmed for your enquiry.
Read the packaging. Check the device.
FTDI · FT2232HL
Laboratory shipment label
Select a marker on the image or a number below. Each field answers a different purchasing question.

Part and carrier notation
The shipment label includes FT2232HL and the word Tray. Reconcile the device code and the actual delivery carrier separately; a shipment note is not the manufacturer’s ordering label.
Shipment quantity
The number shown is the quantity recorded for this shipment. It is not a live stock balance or a quantity reserved for a new order.
Laboratory destination
The destination identifies where this material was sent for inspection. The test scope and findings belong in the corresponding laboratory report.
Keep the complete manufacturer label, the shipment record and the inspection report linked to the offered lot.
Discuss this requirement ↗FTDI · FT2232HL
Moisture-barrier bag label
Select a marker on the image or a number below. Each field answers a different purchasing question.

Moisture sensitivity
The photographed bag shows Level 3. Obtain a fully readable handling label and the opening history for the offered lot before agreeing assembly acceptance.
Assembly temperature
The legible temperature field shows 260°C. Keep this packaging instruction separate from the device’s operating-temperature rating, and check the applicable assembly specification.
Request a clear seal and handling record for the offered lot. Small or obscured print in a photograph should not become an assumed acceptance limit.
Discuss this requirement ↗Compare the chip’s top marking
The device photograph is a separate identity check. Compare it with the complete ordering and packaging records.
Device top marking
FTDI
FT2232HL
Select a marker on the image or a number below. Each field answers a different purchasing question.

Device marking
The visible marking identifies the HL device. Do not substitute HQ or another package merely because the FT2232H family name matches.
Additional marking lines
Keep these strings with the photograph. Decode them only using the applicable FTDI marking reference rather than treating every character as a date.
Pin-one orientation
The visible corner feature helps the assembly team orient the package. A photograph does not confirm the internal configuration or electrical behaviour.
For FT2232HL, keep package identity, carrier form and any programmed configuration separate in the RFQ.
Discuss this requirement ↗Agree inspection around your board.
Start with identity and condition: full ordering code, outer labels, package, top marking, terminals and packing. Ask for photographs and findings tied to the proposed lot.
For functional work, agree the host setup, driver, configuration, test fixture, interface operations, sample count and pass criteria. Any programming or destructive work needs approval before it begins.
Read labels and packing codesVisual inspection
Specify package identity, leg or pad condition, top-mark observations and dimensional checks appropriate to the package. These checks do not establish the whole software interface.
Functional acceptance
Define enumeration, channel use, configuration and data-transfer requirements. Your approved board and host setup are the reference for an application test.
Report and release
Agree what must appear in the report, who reviews exceptions and what happens to tested samples. Release follows the accepted lot and the agreed scope.
Read the findings, not just the sticker.
These report excerpts illustrate how observations are recorded. Request the report identifying the actual part, sampled lot and agreed tests for your order.
Where this purchase fits.
These are procurement contexts for designs that already specify the device. They are not substitution approvals.
Industrial control boards
A missing interface IC can delay an otherwise complete controller build. Retain the approved BOM and specify the first quantity that lets your EMS start assembly.
Programming and test equipment
Ask for functional checks that follow the fixture’s actual host software and interface use. A USB device appearing in the operating system is only one test point.
Service and repair production
Keep the package, configuration and software baseline of the existing design. Confirm acceptable date codes and sample acceptance before committing to the full service quantity.
Before you send the RFQ.
Can a similarly named FTDI device replace this one?
Confirm the full part number against the released BOM. Package, channel count, interface mode and software configuration must be checked by your engineering team before any substitute is accepted.
Can I buy a split quantity?
Tell us the minimum useful quantity, accepted date codes and whether split packing is allowed. We confirm the available pack, lot identification and handling conditions in the quotation.
What if the test scope is not settled yet?
Explain the concern and provide the acceptance specification you have. We can discuss the laboratory’s feasible methods before confirming scope, timing and cost. A requested test is not automatically an agreed or completed test.
Request FT2232HL.
Send the quantity, required arrival date and destination. We review our inventory and established supply relationships, then confirm the offered lot, inspection and delivery terms.
Request a quotationInclude what your receiving team needs.
Include the approved package, packing preference, host software or driver and any fixed device configuration. State which interface operations matter to receiving acceptance.
Inspection starts with an agreed part and lot, sample quantity, method, limits, report requirements and disposition of tested samples.
Your enquiry starts a supply review; it does not reserve a displayed quantity.