Skip to content
Independent electronic component distributionChina supply. International business.[email protected]

AMD / Xilinx FPGA and SoC supply.

Xilinx FPGA and SoC requirements for acquisition cards, recorders, FPGA carriers, vision processing and communications boards. We review the complete device code, source conditions, lot evidence and customer-approved inspection before release.

XC6SLX9-2FTG256I shipment photograph. View the component page for the exact device and lot details.
XC6SLX9-2FTG256I shipment photograph. View the component page for the exact device and lot details.

For board OEMs and EMS purchasing

Keep the FPGA tied to the released assembly.

For Xilinx chip-down board designs, the OEM controls the approved device and the OEM or EMS may place the component order. Specify the complete packaged-IC ordering code, BOM revision and configuration-acceptance owner; distinguish these purchases from finished development boards or SoMs.

Prepare the OEM / EMS approval brief

Acquisition cards & recorders

PCIe/PXIe capture, playback and FMC converter boards: preserve the validated device, timing and memory requirements.

Carriers & vision boards

Chip-down designs, frame grabbers and SoMs: keep the package, grade and configuration target under engineering control.

Communications hardware

RF processing and programmable interfaces: quote the actual BOM, including discrete analog devices only where specified.

Control & industrial I/O

Released control and interface boards: align source approval, incoming inspection and delivery to your assembler.

Choose the procurement path for your design.

Start with the family when you are comparing requirements. Open the exact-device page when the released order code is already known.

Legacy FPGA and configuration requirements.

Keep the supported board, programming files and package together. These pages address distinct devices and roles.

Read the device with its shipment record.

Compare the exact package, grade and receiving conditions. Each page includes supplied photographs, an interactive marking guide and device-specific inspection questions.

Specify the complete Zynq-7000 requirement.

Keep device, package, speed, grade and board-level acceptance together.

Independent supply for your approved devices

Production buyers often need continuity for an approved device rather than a new design selection. Send the exact ordering code already on your BOM and identify any engineering-approved alternatives separately.

Artix 7 FPGA and Zynq 7000 SoC family information comes from AMD’s technical documentation. ICstoq supplies independently and does not claim AMD authorization, manufacturer warranty coverage or availability across the full portfolio.

About our independent distribution model

Check the exact ordering model

Keep device identity and offered-lot details separate.

The most useful RFQ starts with an approved full manufacturer part number, then adds your commercial and acceptance requirements. Use the checks below to make those requirements clear.

What to include in your AMD / Xilinx FPGA and SoC supply. enquiry
CheckWhy it mattersWhat to send
FPGA or SoC identityThe processor and programmable-logic architecture differs by family.Give the complete approved part number.
Speed and operating gradeGrade characters are part of the orderable device identity.Retain the full speed and grade suffixes.
Package and ball mapPackage resemblance does not establish footprint compatibility.Confirm the exact package option against the approved design.
Moisture and lot requirementsHandling history and package sealing need their own evidence.State packing, date-code and source-document acceptance criteria.

Source documents and acceptance

Define what needs to be verified before the order.

For BGA devices, external images can help document package and ball condition, while other agreed methods address specific structural questions. None of those methods alone proves full device function or compatibility with your bitstream.

Any configuration or electrical testing needs an agreed method and fixture. We clarify laboratory scope and available lot documentation before you accept a supply option.

Inspection report example · Read the analysis and sample results.

Manufacturer references

Use the original technical documents to check device identity. These links are not an indication of authorization or current stock.

AMD Artix 7Official FPGA family reference.Manufacturer website · opens a new tabAMD Zynq 7000Official SoC family reference; exact-order checks still apply.Manufacturer website · opens a new tab

References reviewed 2026-11-26.

Continue your component enquiry

Browse related procurement guidance or send an unlisted requirement.

Use these related pages to narrow the device identity and the evidence needed for your order. If your exact part is not listed, send the complete MPN and quantity. We review available stock and additional supply options against your requirements.

Pricing, lot details and delivery are confirmed in the quotation. For multiple parts, send your BOM with one ordering code per line.

Before you enquire

Can an inspected FPGA be assumed to run our design?

No. Physical inspection and application validation are different tasks. Define any configuration or functional acceptance testing explicitly.

Do you list live AMD inventory here?

This is a procurement guide. Current stock, lot details and delivery are confirmed for the exact code and quantity in your enquiry.

AMD/Xilinx inspection: identity, condition and grade.

Our process combines experienced source and label review with independent inspection of the actual lot.

Preserve the approved target

Send the full ordering code, package, speed and temperature designation, quantity, date-code limits and required arrival date. Use the applicable family ordering guide to interpret every suffix. Changes to the released device require your engineering approval.

Resolve identity gaps before acceptance

Compare device markings with tray, bag and carton records. If a supplier has obscured a 2D identifier, disclose that condition before order acceptance and review what evidence remains. A plausible packaging label does not restore a missing device-to-lot link.

A readable code alone is not an authenticity conclusion. AMD explains the limits of Device Lookup outside its authorized sales channel.

Inspect before onward testing

After our incoming review, regular independent partners, normally ICLab, inspect appearance, markings, lid and substrate condition, edges, solder balls and package dimensions under the agreed scope. Signs of handling or rework are reviewed before dispatch to the next laboratory.

Unresolved findings can stop the purchase entirely. Clear top markings do not cancel a failed substrate or condition check.

Agree what grade testing can establish

Where identity or grade evidence is limited, discuss additional electrical, parametric, functional or application-board tests and agreed temperature limits with White Horse Laboratories, GETS or another approved laboratory.

The laboratory must confirm support, fixtures or programs, voltage and timing coverage, sample quantities and pass criteria. Additional work is scoped and priced in advance. A room-temperature power-on, JTAG identity read or speed check alone does not establish industrial-temperature grade.

Testing demonstrates behavior under the conditions examined. It does not recreate the manufacturer’s grade assignment or replace missing traceability. We do not silently downgrade an industrial requirement.

Plan the next build around the approved device.

For a repeat build or an end-of-life supply bridge, separate confirmed demand from forecast quantities. Include the required build dates and any manufacturer notice that prompted the enquiry.

Review the actual orderable code and notice with your engineering owner before assuming a family-wide change. Agree date-code limits, storage and receiving conditions for each proposed lot; a previous shipment does not reserve the next one.

Bring us your exact requirement.

Full part number. Quantity. Required date.
We will review the supply options and the evidence your order needs.

Before you confirm the lot.

Keep the device family, speed, package and grade in the ordering code. Reconcile manufacturer identity with the moisture-handling label and the actual pack quantity.

Read the illustrated label guide
Image detailFit to view