Skip to content
Independent electronic component distributionChina supply. International business.[email protected]

Older-stock BGA inspection

Clear markings do not settle the condition of an older-stock BGA.

Anonymised laboratory close-up of solder-ball condition. Educational case; not an ICstoq shipment.

25 samples.
One failed visual inspection.

This anonymised laboratory case concerns older-stock BGA FPGA samples from a 2022 date-code lot, recorded as 2229. It is a purchasing reference, not an ICstoq shipment or an offer of the illustrated material.

24 visual passes · 1 visual failure

What was recorded

All 25 samples underwent external visual inspection. Markings were clear and complete, with no observed secondary coating, grinding or package-body breakage of the kind checked in the marking review. Separate substrate and ball observations are detailed below.

One randomly selected sample was measured; the reported dimensions were within the datasheet limits. That single measurement does not establish dimensional conformity of every sample.

The supplied summary describes generally normal BGA observations with one sample showing severe residue and solder-ball deformation. That sample failed the visual assessment.

Inspect the observation, then decide the disposition.

Select a finding to see the actual laboratory close-up and the purchasing question it raises. Findings may overlap on the same sample; they must not be added together as six rejected devices.

Anonymised laboratory close-up · substrate edges. No device identity is shown.

2 samples · minor substrate chips

The summary records minor substrate damage on two samples. An observation is not automatically a rejection: the recorded final result was 24 visual passes and one failure.

Before you accept the lot

Ask for location, scale and severity. Agree the acceptance rule for edge damage before sampling.

Age is a reason to ask better questions.

It is not a stand-alone explanation of the defect.

Original identity and physical condition are different decisions.

A part described as original can still have handling damage, contamination or an assembly-related concern. Clear markings and an intact order code cannot close every receiving question.

The record does not establish the cause.

The material had a 2022 date code. The supplied observations alone do not prove that storage duration caused the chips, scratches, residue or deformation. Storage, handling and packaging history should be investigated rather than guessed.

A visual pass has a defined boundary.

The recorded 24 passes concern the stated visual inspection. They do not establish full electrical performance, remaining service life, an authenticity certification or qualification of a finished PCBA.

Write the acceptance agreement before the sample leaves.

Use this checklist to prepare a discussion with purchasing, engineering and the inspection laboratory.

Record the material

Identify the exact part privately, each lot and its quantity. Ask for original packaging records, opening dates, storage information and handling history. Keep photographs attached to the sample identities.

Define the decision

Name the method, sample count, dimensional and cosmetic criteria, permitted cleaning or destructive work, report requirements and who can release the lot. Decide the response to a failed sample before the result arrives.

0 of 5 details ready for review

Bring the finding into your purchasing process.

The case is a method example. Your enquiry should identify the actual material and the result your receiving team needs.

Image detailFit to view