LAN96455ST-I/8MW
For LAN96455ST-I/8MW, retain the five-port device, industrial option and 128-pin TQFP package. The reel identifier belongs on the order even when it is absent from the chip’s top mark.
Keep five ports and the footprint.
- Switch
- LAN96455S
- Package option
- 8MW
Ordering and acceptance reference · supply confirmed by quotation
Keep every ordering field in the comparison.
Select a code segment, then compare the offered identity with the released BOM. The source references below establish ordering context, not live availability.
| Order / record | What it means | Before you accept |
|---|---|---|
| 8MW / 8NW | The package options have different footprints. | Compare the complete suffix with the approved PCB. |
| T packing field | The catalogue identifier and chip marking need not display the same string. | Check the shipping label before treating an absent top-mark T as a discrepancy. |
| Managed / unmanaged operation | Configuration and software requirements differ. | Retain the board’s strapping, EEPROM or software setup in the acceptance brief. |
Resolve the decision behind the shortage.
Choose the situation that applies to your order. Each one changes what purchasing, engineering and the test owner need to agree.
Restore the full package requirement.
An offer abbreviated to LAN96455S leaves carrier and package unresolved. Ask for the offered catalogue code and label before approving the purchase for your released board.
LAN96455ST-I/8MW and assembly requirements.
Compare the right records.
The manufacturer’s identification section explains that the packing identifier is not marked on the package. Reconcile the device mark, shipping label and order record together.
Both pack-label and device-mark photographs.
Separate a shortage purchase from a design change.
Agree the intended managed or unmanaged setup with engineering. For an existing product, use its known configuration and define link, traffic and reset checks before accepting a sample.
Mode, board revision, configuration and errata review.
Read the fields. Keep the device context.
Explore this supplied USB5744 distributor label. It belongs to a different device; use the offered lot’s own label to establish identity and handling requirements.
For LAN96455ST-I/8MWRequest this exact LAN96455ST-I/8MW shipping label. Do not use a missing T in the device top mark as a stand-alone rejection; compare it with the manufacturer’s marking guidance.
Distributor packaging label
Microchip
USB5744BT-I/2GX01
Select a marker on the image or a number below. Each field answers a different purchasing question.

Manufacturer versus distributor code
MFR PN is the Microchip identifier. The longer PN above is a distributor catalogue code and includes its own fulfilment suffix.
Lot and date
The date and lot occupy separate fields. Keep both when asking for one-lot material or checking whether a split shipment meets your receiving rules.
Seal timestamp
This is the distributor’s seal record. It does not establish the silicon manufacturing date or the entire storage history.
Moisture handling
This USB5744 pack states MSL 3 and 168 hours. Use the requested device’s own package classification and applicable handling conditions; these values do not transfer to another device.
Pack quantity
The illustrated distributor pack carries its own quantity. A distributor cut-tape count is not the manufacturer’s standard full-reel quantity.
For this USB hub, retain /2GX01 and confirm the accepted carrier, lot and moisture-handling record.
Discuss this requirement ↗Agree the acceptance brief before testing.
Identity, unused condition and the complete order code are essential. Your device’s programming, assembly and operating requirements still need their own checks.
Identity and lead condition
Use the 8MW package drawing when inspecting leads and dimensions. A 156-pin package comparison cannot approve a 128-pin order.
Configuration record
Identify strapping, stored settings or driver setup used for the sample. Record the software version and any applicable revision restrictions.
Port behaviour
Name the wired ports, traffic conditions and reset sequence to test. Visual inspection does not verify a network path or software configuration.
Agree the lot, sample count, method, fixture, limits, report and sample disposition. Electrical or specialised analysis depends on laboratory feasibility; it is not implied by an external visual inspection.
Give each method a defined purpose.
Internal images and external photographs provide different observations. Agree the specific concern and comparison reference before requesting analysis. This process image does not establish the identity or electrical function of the device being sourced.
Explore inspection reportsSupport the board already in service.
A targeted component purchase can support your existing EMS or repair team. Keep the released board, programming baseline and receiving requirements together while sourcing the missing line.
Plan an OEM / EMS shortage purchaseIndustrial control networks
Equipment makers can fill a single switch shortage while retaining the approved PCB and network design.
Networked measurement systems
A small production batch may depend on replicating the same port and management configuration.
Send the requirement your board needs.
ICstoq reviews our inventory and established China supply relationships against the complete order code, quantity, required arrival date and destination. The quotation confirms the offered lot, inspection scope and delivery terms.
Send your enquiryInclude these details
- LAN96455ST-I/8MW and required carrier
- Managed/unmanaged configuration, board and software revision
- Accepted lot/revision and link, traffic, reset checks
Identify fixed requirements and any alternatives already approved by your engineering team. We agree feasible inspection work and sample acceptance before proceeding.